Y60 ICD-10-CA category: Unintentional cut, puncture, perforation or haemorrhage during surgical and medical care
Y60 isn’t a code on its own. Choose one of the 10 codes beneath it, the one the documentation supports.
Official description
Y60Unintentional cut, puncture, perforation or haemorrhage during surgical and medical care
ICD-10-CA · Canada
Codes in Y60
Y60 isn’t a code on its own. Open the code that matches what the note documents.
Y60.0Unintentional cut, puncture, perforation or haemorrhage during surgical operationY60.1Unintentional cut, puncture, perforation or haemorrhage during infusion or transfusionY60.2Unintentional cut, puncture, perforation or haemorrhage during kidney dialysis or other perfusionY60.3Unintentional cut, puncture, perforation or haemorrhage during injection or immunizationY60.4Unintentional cut, puncture, perforation or haemorrhage during endoscopic examinationY60.5Unintentional cut, puncture, perforation or haemorrhage during heart catheterizationY60.6Unintentional cut, puncture, perforation or haemorrhage during aspiration, puncture and other catheterizationY60.7Unintentional cut, puncture, perforation or haemorrhage during administration of enemaY60.8Unintentional cut, puncture, perforation or haemorrhage during other surgical and medical careY60.9Unintentional cut, puncture, perforation or haemorrhage during unspecified surgical and medical careNotes for Y60
As CIHI prints them, with any note Y60 takes from the headings above it.
Includes
- Complications of medical devicescorrect drug properly administered in therapeutic or prophylactic dosage as the cause of any adverse effectmisadventures to patients during surgical and medical caresurgical and medical procedures as the cause of abnormal reaction of the patient, or of later complication, without mention of misadventure at the time of the procedureFrom Y40-Y84 Complications of medical and surgical care
Excludes
Conditions classified elsewhere.
- Breakdown or malfunctioning of medical device (during procedure) (after implantation) (ongoing use) (Y70-Y82)medical devices associated with adverse incidents due to external causes classified elsewhere (V01-Y59, Y85-Y87, Y89)surgical and medical procedures as the cause of abnormal reaction of the patient, without mention of misadventure at the time of the procedure (Y83-Y84)From Y60-Y69 Misadventures to patients during surgical and medical care
- Accidental overdose of drug or wrong drug given or taken in error (X40-X44)From Y40-Y84 Complications of medical and surgical care
Note
- This chapter, which in previous revisions of ICD constituted a supplementary classification, permits the classification of environmental events and circumstances as the cause of injury, poisoning and other adverse effects. Where a code from this section is applicable, it is intended that it shall be used in addition to a code from another chapter of the Classification indicating the nature of the condition. Most often, the condition will be classifiable to Chapter XIX, Injury, poisoning and certain other consequences of external causes (S00-T98). Causes of death should preferably be tabulated according to both Chapter XIX and Chapter XX, but if only one code is tabulated then the code from Chapter XX should be used in preference. Other conditions that may be stated to be due to external causes are classified in Chapters I to XVIII. For these conditions, codes from Chapter XX should be used to provide additional information for multiple-condition analysis only.From Chapter 20: External causes of morbidity and mortality (V01-Y98)
Where Y60 sits
- 1ChapterChapter 20: External causes of morbidity and mortality (V01-Y98)
- 2Block Y40-Y84Complications of medical and surgical care
- 3Block Y60-Y69Misadventures to patients during surgical and medical care
- 4Category Y60Unintentional cut, puncture, perforation or haemorrhage during surgical and medical care
Source and release
- Data release
- ICD-10-CA · FY 2026–2027
- Effective date
- Apr 1, 2026
- Publisher
- CIHI
This page is built from the ICD-10-CA catalog that Vero Codes reads when it suggests codes: Canadian Institute for Health Information’s FY 2026–2027 release, imported from the publisher’s file and checked against it. The description, notes and structured data come from the same record.
Frequently asked questions
Is Y60 a valid ICD-10-CA code?
No. Y60 (Unintentional cut, puncture, perforation or haemorrhage during surgical and medical care) is a category heading in CIHI’s ICD-10-CA FY 2026–2027 release. It holds 10 codes; record the one the documentation supports.
Where is Y60 in ICD-10-CA?
Y60 sits under Y60-Y69 Misadventures to patients during surgical and medical care, within Y40-Y84 Complications of medical and surgical care, within Chapter 20: External causes of morbidity and mortality (V01-Y98).
What coding notes apply to Y60?
ICD-10-CA lists Excludes, Includes, Note notes for Y60, including those from the headings it sits under. They are listed on this page with where each one comes from.
Which ICD-10-CA release does this page use?
It uses CIHI’s FY 2026–2027 release, in effect from Apr 1, 2026 to Mar 31, 2027. It is a reference: confirm the code against the current list and the payer’s rules before you submit it.
Codes beside Y60
View Y60-Y69Y61Foreign object accidentally left in body during surgical and medical careY62Failure of sterile precautions during surgical and medical careY63Failure in dosage during surgical and medical careY64Contaminated medical or biological substancesY65Other misadventures during surgical and medical careY66Nonadministration of surgical and medical careY69Unspecified misadventure during surgical and medical care